MantisBT - ParaView
View Issue Details
0010111ParaViewBugpublic2010-01-08 15:572010-09-15 22:07
Alan Scott 
Utkarsh Ayachit 
normalminoralways
closedfixed 
 
3.10 
0010111: Show center and reset center are not working properly
Trunk, local server, XP.
This requires the new "Rescale Data Range Mode" code, but probably isn't caused by this new code.

* Edit/ Settings/ General/ Rescale Data Range Mode/ Use last timestep.
* Open can.exo. Apply. (Notice that we open Can.exo at the last frame.)
* First frame.
<Bug 1> Notice that the "Reset Center" icon is grayed out. It should be useable.
* Click Show center icon.
* Click Show center icon.
<Bug 2> Notice that the center has moved. All that should have happened is the center should have lost visibility, and then become visible again. It should not have moved.
No tags attached.
related to 0011232closed Utkarsh Ayachit Pick center does not work 
Issue History
2010-01-08 15:57Alan ScottNew Issue
2010-04-16 01:55Utkarsh AyachitTarget Version3.8 => 3.10
2010-04-16 01:55Utkarsh AyachitAssigned To => user3172
2010-04-16 01:55Utkarsh AyachitStatusbacklog => tabled
2010-09-01 11:30Utkarsh AyachitAssigned Touser3172 =>
2010-09-01 11:30Utkarsh AyachitTarget Version3.10 => 3.10.shortlist
2010-09-15 17:07Utkarsh AyachitNote Added: 0022237
2010-09-15 17:07Utkarsh AyachitStatustabled => @80@
2010-09-15 17:07Utkarsh AyachitFixed in Version => 3.10
2010-09-15 17:07Utkarsh AyachitResolutionopen => fixed
2010-09-15 17:07Utkarsh AyachitAssigned To => Utkarsh Ayachit
2010-09-15 22:07Alan ScottNote Added: 0022249
2010-09-15 22:07Alan ScottStatus@80@ => closed
2010-09-15 22:08Alan ScottRelationship addedrelated to 0011232

Notes
(0022237)
Utkarsh Ayachit   
2010-09-15 17:07   
commit 31bf200400faf95e92c61e1e7e4ad6015ea98ae1
Author: Utkarsh Ayachit <utkarsh.ayachit@kitware.com>
Date: Wed Sep 15 17:06:57 2010 -0400

    Fixed BUG 0010111. Fixed discrepancies in the Axes toolbar.
(0022249)
Alan Scott   
2010-09-15 22:07   
Most excellent!

Tested Linux, trunk, local server.