MantisBT - ParaView
View Issue Details
0011191ParaViewBugpublic2010-08-30 20:472016-08-12 09:58
Alan Scott 
Kitware Robot 
normalminoralways
closedmoved 
 
 
0011191: isovolume wrong for cth amr point data
ParaView trunk, local server, Windows.
Open the spcta_a.[0-3] dataset.
Cell to Point filter.
isoVolume.
Bug - notice that the object is hollow, and has bad normals (bad lighting).

This needs to be fixed for 3.10.
No tags attached.
Issue History
2010-08-30 20:47Alan ScottNew Issue
2010-11-09 09:42Utkarsh AyachitTarget Version3.10 => 3.10.shortlist
2016-07-13 18:21Alan ScottAssigned To => Alan Scott
2016-07-13 18:21Alan ScottNote Added: 0036424
2016-07-13 18:21Alan ScottStatusexpired => backlog
2016-07-13 18:21Alan ScottResolutionopen => reopened
2016-07-13 19:06Alan ScottAssigned ToAlan Scott =>
2016-08-12 09:58Kitware RobotNote Added: 0037876
2016-08-12 09:58Kitware RobotStatusbacklog => closed
2016-08-12 09:58Kitware RobotResolutionreopened => moved
2016-08-12 09:58Kitware RobotAssigned To => Kitware Robot

Notes
(0036424)
Alan Scott   
2016-07-13 18:21   
Changing to backlog. This is still a bug.

The root cause of the problem is that the Iso Volume filter is keeping data from equal to or greater than a min, and less than (but not equal to a max.) We need to make it less than or equal to max.
(0037876)
Kitware Robot   
2016-08-12 09:58   
Resolving issue as `moved`.