MantisBT - ParaView
View Issue Details
0005360ParaViewBugpublic2007-07-17 18:582010-03-17 16:38
Alan Scott 
Berk Geveci 
normalfeaturealways
closedfixed 
 
3.8 
0005360: Feature request - option to read in data from all time steps
I know that there are lots of arguments against having an option to read in all time steps before setting default values, but we keep getting requests from users. Here is the latest:

I have finally figured out that the rescale Data Range function works on
the current time step rather than across all times steps This was
disconcerting because I could not find some data in the visualizer
because the range was set by another time step. Any way I can change
this default to look over all the data to get the range or set it
explicitly?
No tags attached.
has duplicate 0010062closed Utkarsh Ayachit Changes to rescale data range 
Issue History
2008-04-09 21:10Berk GeveciCategory => 3.6
2008-04-09 21:12Berk GeveciNote Added: 0011247
2009-02-16 15:33Ken MorelandCategory3.6 => 3.8
2009-05-13 13:42Utkarsh AyachitTarget Version => 3.8
2009-08-24 16:19Alan ScottCategory => Bug
2009-08-24 16:19Alan ScottTarget Version3.8 => 3.6.2
2009-08-24 16:57Alan ScottNote Added: 0017198
2009-09-08 14:43Alan ScottNote Added: 0017341
2009-09-08 14:43Alan ScottTarget Version3.6.2 => 3.8
2009-11-18 14:56Alan ScottNote Added: 0018476
2010-01-18 22:33Alan ScottRelationship addedduplicate of 0010097
2010-01-18 22:34Alan ScottRelationship deleted0010097
2010-01-18 22:35Alan ScottRelationship addedhas duplicate 0010062
2010-03-17 16:38Alan ScottNote Added: 0019946
2010-03-17 16:38Alan ScottStatustabled => closed
2010-03-17 16:38Alan ScottResolutionopen => fixed

Notes
(0011247)
Berk Geveci   
2008-04-09 21:12   
Maybe we could add a button to the information tab to get the range for all time steps?
(0017198)
Alan Scott   
2009-08-24 16:57   
For 3.6.2, lets limit this bug to just reading in the last timestep. It would be really nice to add an option to the settings dialog that allows the user to choose either the first or last timestep. Default to the last time step (matching EnSight).

What should we do for 3.8.0 - write up another bug that is more thorough?
(0017341)
Alan Scott   
2009-09-08 14:43   
As per Utkarsh's suggestion, I am moving this back to 3.8. It really should be fixed correctly (whatever we decide that means) for 3.8.
(0018476)
Alan Scott   
2009-11-18 14:56   
For 3.8, I would like to propose the following:
* User selectable options. Nicer again would be a threshold that we could set in the settings panel - above some size one functionality, below some size, and different functionality.
  - ParaView goes to last time step, sets min/max range from last time step. (Default, or for small data)
  - ParaView stays with first time step. (for large data)
  - ParaView updates every time step. (Only if user selects this option.)
(0019946)
Alan Scott   
2010-03-17 16:38   
Duplicate. Actually fixed with bug number 10062.