MantisBT - ParaView
View Issue Details
0006146ParaView(No Category)public2007-12-11 10:092008-03-07 07:56
David Karelitz 
 
normalmajoralways
closedfixed 
 
 
0006146: (MARS-normal) Calculator causes upstream filters/readers to re-execute
When you apply a calculator filter (after accepting the changes from any upstream filters), the calculator causes all the upstream filters to re-execute. This may be related to the bug about issues when the first timestep in a file is not 0, but I'm not positive
No tags attached.
Issue History
2007-12-11 10:09David KarelitzNew Issue
2007-12-11 12:29David KarelitzNote Added: 0009859
2008-01-17 17:54David KarelitzStatusbacklog => closed
2008-01-17 17:54David KarelitzNote Added: 0010181
2008-01-17 17:54David KarelitzResolutionopen => fixed
2008-03-07 07:56Berk GeveciTarget Version => MARS
2011-06-16 13:10Zack GalbreathCategory => (No Category)

Notes
(0009859)
David Karelitz   
2007-12-11 12:29   
The problem seems to be with CellToPoint. Just about anything causes it to re-execute.
(0010181)
David Karelitz   
2008-01-17 17:54   
This doesn't look like a bug anymore. It seems like it was related to compute normals on contour causing ghost cells to be needed.