0007014: rescale to data range does not work on thresholded data
Load in file. Threshold on variable. Now colour thresholded data with same variable. Press 'Rescale to Data Range'. Produces colour bar 0..1 instead of proper range. (the Information tab does show the correct range).

This is with the 3.3-cvs version from around 1/5/8
No tags attached.
Issue History
2008-05-14 04:20MattijsNew Issue
2008-05-14 10:10Ken MorelandStatusbacklog => @80@
2008-05-14 10:10Ken MorelandResolutionopen => unable to reproduce
2008-05-14 10:10Ken MorelandAssigned To => Ken Moreland
2008-05-14 10:10Ken MorelandNote Added: 0011895
2008-05-14 19:28Alan ScottStatus@80@ => closed
2008-05-14 19:28Alan ScottNote Added: 0011934
2008-05-16 08:57MattijsStatusclosed => @20@
2008-05-16 08:57MattijsResolutionunable to reproduce => reopened
2008-05-16 08:57MattijsNote Added: 0011959
2008-05-16 09:22Ken MorelandStatus@20@ => closed
2008-05-16 09:22Ken MorelandResolutionreopened => fixed
2009-05-13 13:58Utkarsh AyachitTarget Version => 3.4
2009-05-13 13:59Utkarsh AyachitFixed in Version => 3.4
2011-06-16 13:10Zack GalbreathCategory => (No Category)

Notes
(0011895)
Ken Moreland   
2008-05-14 10:10   
Works for me for CVS build last night (5/13/08). I used the Wavelet source, showed the surface, colored by RTData, thresholded on RTData, rescaled based on the output of the threshold. The threshold range was fine.
(0011934)
Alan Scott   
2008-05-14 19:28   
Tested local server, using disk_out_ref.exo and Temp. Looks correct to me.
(0011959)
Mattijs   
2008-05-16 08:57   
Can't repeat it myself either. Must have made mistake. Sorry.