MantisBT - ParaView | |||||
| View Issue Details | |||||
| ID | Project | Category | View Status | Date Submitted | Last Update |
| 0009422 | ParaView | Bug | public | 2009-08-14 11:42 | 2016-08-12 09:57 |
| Reporter | Sven Buijssen | ||||
| Assigned To | Utkarsh Ayachit | ||||
| Priority | normal | Severity | minor | Reproducibility | always |
| Status | closed | Resolution | moved | ||
| Platform | OS | OS Version | |||
| Product Version | 3.6 | ||||
| Target Version | Fixed in Version | ||||
| Project | |||||
| Topic Name | |||||
| Type | |||||
| Summary | 0009422: VCR plays too many files in file series after load state event followed by load new file series | ||||
| Description | Load some file series, e.g. ParaViewData/Data/FileSeries/blow..vtk (=> 10 files) Save state. Disconnect. Load state. Load a different file series consisting of less files, e.g. only 2 files. Delete first file series Play series with VCR toolbar. => Not 2 frames, but 10 frames are played. It does not happen if you omit the save/load state steps. Happens for ParaView 3.6.1 and a top of cvs build. If desired I can provide a screen capture. | ||||
| Steps To Reproduce | |||||
| Additional Information | |||||
| Tags | No tags attached. | ||||
| Relationships | |||||
| Attached Files | |||||
| Issue History | |||||
| Date Modified | Username | Field | Change | ||
| 2009-08-14 11:42 | Sven Buijssen | New Issue | |||
| 2010-04-20 17:24 | Sven Buijssen | Note Added: 0020307 | |||
| 2010-05-07 09:41 | Utkarsh Ayachit | Status | backlog => tabled | ||
| 2010-05-07 09:41 | Utkarsh Ayachit | Assigned To | => Utkarsh Ayachit | ||
| 2016-08-12 09:57 | Kitware Robot | Note Added: 0037681 | |||
| 2016-08-12 09:57 | Kitware Robot | Status | expired => closed | ||
| 2016-08-12 09:57 | Kitware Robot | Resolution | open => moved | ||
| Notes | |||||
|
|
|||||
|
|
||||
|
|
|||||
|
|
||||