MantisBT - ParaView
View Issue Details
0009422ParaViewBugpublic2009-08-14 11:422016-08-12 09:57
Sven Buijssen 
Utkarsh Ayachit 
normalminoralways
closedmoved 
3.6 
 
0009422: VCR plays too many files in file series after load state event followed by load new file series
Load some file series, e.g. ParaViewData/Data/FileSeries/blow..vtk (=> 10 files)
Save state.
Disconnect.
Load state.
Load a different file series consisting of less files, e.g. only 2 files.
Delete first file series
Play series with VCR toolbar.
=> Not 2 frames, but 10 frames are played.

It does not happen if you omit the save/load state steps.

Happens for ParaView 3.6.1 and a top of cvs build.

If desired I can provide a screen capture.
No tags attached.
Issue History
2009-08-14 11:42Sven BuijssenNew Issue
2010-04-20 17:24Sven BuijssenNote Added: 0020307
2010-05-07 09:41Utkarsh AyachitStatusbacklog => tabled
2010-05-07 09:41Utkarsh AyachitAssigned To => Utkarsh Ayachit
2016-08-12 09:57Kitware RobotNote Added: 0037681
2016-08-12 09:57Kitware RobotStatusexpired => closed
2016-08-12 09:57Kitware RobotResolutionopen => moved

Notes
(0020307)
Sven Buijssen   
2010-04-20 17:24   
Problem still persists for PV 3.8.0 RC1
Additionally, extending the instructions given above by an extra "Save State. Disconnect. Load State", still 10 frames are played even though Object Inspector - Information - Time lists less than 10 time indices (2 in above's example).
(0037681)
Kitware Robot   
2016-08-12 09:57   
Resolving issue as `moved`.