MantisBT - ParaView
View Issue Details
0009532ParaViewBugpublic2009-09-14 11:232016-08-12 09:57
Ken Moreland 
Julien Finet 
normalminorhave not tried
closedmoved 
 
 
0009532: Scatter plot axes must be scaled independently
Right now all the axes in a scatter plot are scaled uniformly, much like in an ordinary 2D or 3D view. This is wrong. It is important to scale each axis independently. To see an example of why, do the following:

1. Load disk_out_ref.ex2. All variables on. Apply.
2. Create a scatter plot view. Make disk_out_ref visible.
3. In the Display panel, change X Coords to Temp and Y Coords to Pres.
4. Click Reset Camera (workaround bug 0009531).

Notice that all the points appear to be on a horizontal line. This is because the temperature is in Kelvins and is in the range of 200-900 whereas the pressure is in atmospheres and is in the range of 0.02-0.03.
No tags attached.
Issue History
2009-09-14 11:23Ken MorelandNew Issue
2009-09-14 11:23Ken MorelandStatusbacklog => tabled
2009-09-14 11:23Ken MorelandAssigned To => Julien Finet
2016-08-12 09:57Kitware RobotNote Added: 0037705
2016-08-12 09:57Kitware RobotStatusexpired => closed
2016-08-12 09:57Kitware RobotResolutionopen => moved

Notes
(0037705)
Kitware Robot   
2016-08-12 09:57   
Resolving issue as `moved`.