MantisBT - ParaView
View Issue Details
0006110ParaView(No Category)public2007-12-03 11:442009-05-13 13:59
Ken Moreland 
Clinton Stimpson 
normalminoralways
closedfixed 
 
3.43.4 
0006110: Variable chooser combo box not updated
The variable chooser combo box in the Active Variable Controls toolbar is not appropriately updated when the variables of the active object change. Here is how to replicate the problem.

1. Load in disk_out_ref.ex2 with NO variables selected. After you select, the variable chooser should only have Solid Color and cellNormals.
2. Turn on all of the variables and reapply the reader. The variables do not show up in the variable chooser.

The variable chooser can be force to update by clicking something else in the pipeline browser and then clicking on the object again. However, it is still very confusing to not see the variables in the chooser immediately after loading them.
No tags attached.
related to 0004005closed Clinton Stimpson Need event from display proxy 
Issue History
2007-12-03 11:44Ken MorelandNew Issue
2007-12-04 17:23Clinton StimpsonRelationship addedrelated to 0004005
2007-12-04 17:23Clinton StimpsonNote Added: 0009820
2008-03-26 12:24Clinton StimpsonStatusbacklog => tabled
2008-03-26 12:24Clinton StimpsonAssigned To => Clinton Stimpson
2008-03-26 12:27Clinton StimpsonStatustabled => closed
2008-03-26 12:27Clinton StimpsonNote Added: 0010920
2008-03-26 12:27Clinton StimpsonResolutionopen => fixed
2008-03-26 12:28Clinton StimpsonStatusclosed => @80@
2008-04-01 16:52Alan ScottStatus@80@ => closed
2008-04-01 16:52Alan ScottNote Added: 0011022
2009-05-13 13:58Utkarsh AyachitTarget Version => 3.4
2009-05-13 13:59Utkarsh AyachitFixed in Version => 3.4
2011-06-16 13:10Zack GalbreathCategory => (No Category)

Notes
(0009820)
Clinton Stimpson   
2007-12-04 17:23   
Need to fix bug 0004005 first.
(0010920)
Clinton Stimpson   
2008-03-26 12:27   
Using new event from vtkSMOutputPort fixes this.
(0011022)
Alan Scott   
2008-04-01 16:52   
Tested client server.