View Issue Details Jump to Notes ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0006270ParaView(No Category)public2008-01-23 15:222008-04-14 19:12
ReporterAlan Scott 
Assigned ToKen Moreland 
PriorityhighSeverityminorReproducibilityalways
StatusclosedResolutionduplicate 
PlatformOSOS Version
Product Version 
Target VersionFixed in Version 
Summary0006270: ParaView checks ranges every keystroke for color editor
DescriptionParaView is checking the range of input data every keystroke again. It should only do this when the field is accepted (hit enter or focus is lost).

ParaView trunk, January 23rd.

Open can.exo., all variables, apply.
Change Color By to DISPL.
Edit color map, uncheck "Automatically Rescale..."
Rescale Range.
Try to change the Minimum to 1.

It would be really nice to get this fixed for 3.4, since it was fixed for 3.2.1.
TagsNo tags attached.
Project
Topic Name
Type
Attached Files

 Relationships
duplicate of 0006127closedClinton Stimpson (MARS-low) Maximum value in Set Scalar Range is checked against the minimum value on every keystroke 

  Notes
(0011306)
Alan Scott (manager)
2008-04-14 19:12

Duplicate

 Issue History
Date Modified Username Field Change
2008-01-23 15:22 Alan Scott New Issue
2008-04-09 18:09 Ken Moreland Relationship added duplicate of 0006127
2008-04-09 18:09 Ken Moreland Duplicate ID 0 => 6127
2008-04-09 18:09 Ken Moreland Status backlog => @80@
2008-04-09 18:09 Ken Moreland Resolution open => duplicate
2008-04-09 18:09 Ken Moreland Assigned To => Ken Moreland
2008-04-14 19:12 Alan Scott Status @80@ => closed
2008-04-14 19:12 Alan Scott Note Added: 0011306
2011-06-16 13:10 Zack Galbreath Category => (No Category)